Search in Brand
Filter Your Search
Category Group
Shop by Category
Shop Potter Electric | Brands We Sell
POTTER PAD300-6DB 6 INCH DETECTOR BASE
The PAD300-6DB is a low-profile, surface-mount base used with Potter’s addressable detectors. The base uses screw clamp terminals that accept wire ranging from 22 to 12 AWG. When installed on recessed electrical boxes, the PAD300-6DB is wide enough to completely cover the back box and the immediate surrounding area. The base is equipped with a locking tab to deter unauthorized removal of the attached detector.
POTTER PAD300-PD PHOTOELECTRIC SMOKE DETECTOR
The Photoelectric Smoke Detector is a listed Analog Addressable smoke detector compatible with fire alarm control panels that utilize the Potter Addressable Device (PAD) protocol. The PAD300-PD is a low profile smoke detector with a wide sensitivity range. The detector and base are made of a durable plastic in an off-white color to blend in with the ceiling. The PAD300-PD has a sensitivity range of 1.1 to 3.5 % per foot and is UL listed. The PAD300-PD features drift compensation and has built in dirty detector warning as well. The PAD300-PD and the control panel communicate over a proven and robust digital communication path and the system analyzes the information at the particular device. The total polling speed is less than five (5) seconds, well under the UL requirements. The detector is compatible with any of the PAD300 series detector bases and simply twists on. The PAD300-PD is addressed using DIP switches in the rear of the detector and can be easily programmed in the field with
POTTER AFC-50, ADDRESSABLE FACP, 99 ZONE
The AFC-50 has a 5 Amp power supply with two Notification Appliance Circuits (NACs) and two Input/Output (I/O) circuits. The NACs are rated at 3 Amps each and the I/Os are rated at 1 Amp each. Each output is regulated and power limited. In addition, each output is uniquely programmable and may be configured for steady signal, strobe synchronization, constant power, door holder power, or releasing.
Potter Electric HUB-M, Single Button Hold-Up Switch
The Model HUB-M provides momentary or latching DPDT contacts for actuating surveillance cameras or other security applications.
POTTER AFC-1000, 1,270 ADDRESS ANALOG FACP
The AFC-1000 has a 10 Amp power supply with six Notification Appliance Circuits (NACs) and four Input/Output (I/O) circuits. The NACs are rated at 3 Amps each and the I/Os are rated at 1 Amp each. Each output is regulated and power limited. In addition, each output is uniquely programmable and may be configured for steady signal, strobe synchronization, constant power, door holder power, or releasing. The strobe synchronization includes Gentex, AMSECO, System Sensor and Cooper/Wheelock and with the exclusive Quadrasync each output may have a unique brand and all strobes will flash together. The I/Os are designed for inputs such as manual release stations and abort switches that will not require polling and react nearly instantaneously.
POTTER PAD300-LFSB ADDRESSABLE LOW FREQ. SOUNDER BASE
The Addressable Low Frequency Sounder Base (PAD300-LFSB) is a sounder base that may be utilized in a variety of applications. The base has a locking feature for the detector that may be used or removed in the field. Once the head is removed, the sounder is accessible in the bottom of the unit. The PAD300-LFSB low frequency sounder base is designed to meet NFPA 72 sleeping space requirements to produce a frequency of 520 Hz +/- 10% with a square wave. It is shown that a lower frequency, centered around 520 Hz, is the ideal to awaken sleeping occupants, even those with mild to severe hearing loss. The base has an independent sounder module that may be programmed as a single station, zone or all call sounder. The PAD300-LFSB passes through the sound pattern sent to the sounder, therefore it may reproduce in any pattern the power supply provides. The PAD300-LFSB does not consume an address on the loop and is fully programmable to operate with any input. Once activated the sounder will also
POTTER PFC-4064, 6 ZONE CONVENTIONAL FIRE ALARM CONTROL PANEL
6 programmable Initiating Device Circuits/System is expandable to 192 input circuits using the IDC-6 expansion module/5.0 amp power Supply/4 Notification Circuit rated at 3.0 Amps/4 × 20 LCD display with system LeDs for clear system status
POTTER AFC-100, ADDRESSABLE FACP, 99 ZONE
The AFC-100 includes two Notification Appliance Circuits (NACs), two Input/Output (I/O) circuits, and a 5 Amp power source. The I/Os are individually rated for 1 Amp, whereas the NACs are each rated for 3 Amps. Each output has a power restriction and is regulated. Additionally, each output can be individually programmed and can be set to produce a steady signal, synchronize strobes, have constant power, power door holders, or release.
POTTER PAD300-DUCTR ANALOG ADDRESSABLE DUCT DETECTOR
The Potter Electric PAD300-DUCTR duct smoke detector provides early detection of smoke and products of combustion present in air moving through HVAC ducts in commercial, industrial and residential applications. The PAD300-DUCTR is compatible with the IPA and AFC/ARC series addressable fire alarm control panels.
The PAD300-DUCTR is designed and built to meet all local requirements, as well as the NFPA regulations regarding duct smoke detectors. Air sampling is accomplished by two (2) tubes which protrude into the duct.
POTTER PAD300-DUCT ANALOG ADDRESSABLE DUCT DETECTOR
The Potter Electric PAD300-DUCT duct smoke detector provides early detection of smoke and products of combustion present in air moving through HVAC ducts in commercial, industrial and residential applications. The PAD300-DUCT is compatible with the IPA and AFC/ARC series addressable fire alarm control panels. The PAD300-DUCT is designed and built to meet all local requirements, as well as the NFPA regulations regarding duct smoke detectors. Air sampling is accomplished by two (2) tubes which protrude into the duct. An exhaust tube of one standard length (7”) is supplied in the installation kit with the smoke duct unit.









