ALTRONIX AL802ULADA, NAC PS, 12/24VDC@8A, 2A OR 4B OUT, RED BC400 ENCL

Item #: AL-AL802ULADA

Product Info

ALAL802ULADA
ALTRONIX CORPORATION
AL802ULADA

NAC POWER EXTENDER 24/12VDC@8 AMP. (2)CLASS A OR (4)CLASS B NAC CIRCUITS. GENERATES SYSTEM SENSOR GENTEX FARADAY AND AMSECO SYNC PROTOCOLS. 1 AMP AUX. OUTPUT UL LISTED FIRE (UL864 UL1481) MEA/CSFM/FM APPROVED. RED ENCLOSURE 15.5“H X 12“W X 4.5“D

Altronix AL802ULADA is an extremely cost effective voltage regulated remote NAC Power Extender. It may be connected to any 24 volt Fire Alarm Control Panel (FACP). Primary applications include Notification Appliance Circuit (NAC) expansion (supports ADA requirements) and providing auxiliary power to support system accessories.

FEATURES:

  • 2-wire horn/strobe Sync mode allows audible notification appliances (horns) and visual notification appliances (strobes) to be silenced/deactivated at the same time.
  • Sync protocols include Potter/Amseco, Gentex®, System Sensor®, and CooperWheelock®.
  • Temporal Code 3, Steady Mode, Input to Output Follower Mode (maintains synchronization of notification appliances circuit).
  • Compatible with 12VDC or 24VDC fire panels.
  • Output loop supervision steered to Input 1 or Input 2.
  • Signal circuit trouble memory (helps identify intermittent loop problems).
  • Common trouble input and output for external trouble signals tie-in.
  • Ground fault detection.

Input
Voltage:

  • 120VAC, 60Hz, 4A.
  • Two (2) Class A or two (2) Class B inputs.
  • Two (2) NC dry contact trigger inputs.
    Input Ratings (INP1 and INP2):
  • 8-30VDC 6.5mA max from FACP.
  • 12V 6.5mA, 24V 6.5mA from FACP.

Output
Voltage:

  • 24VDC power-limited outputs.
    Current:
  • 8A max. total alarm current.
  • 2.5A max. current per output.
    Auxiliary:
  • 1A.
    Other:
  • Thermal and short circuit protection with auto reset.
  • Filtered and regulated outputs.
  • Four (4) Class B, or TWO (2) Class A, or
    One (1) Class A and Two (2) Class B.

Battery Charging

  • Charging voltage is 26.2-26.4VDC.
  • Built-in charger for sealed lead acid or gel type batteries.
  • Automatic switchover to stand-by battery when AC fails.
  • Zero voltage drop when switching over to battery backup.
    (Batteries are sold separately).

Supervision

  • AC Failure: Form “C” contacts.
  • Battery: Form “C” contacts.

Indicators (LED)

  • AC Power (Green): Input voltage is present.
  • DC Output (Red): Powered.
  • Logic Board (Red and Green): Output status.

Temperature

  • Operating: 0° C to 49° C (32° F to 120° F).
  • Storage: – 20° C to 70°C ( – 4° F to 158° F).
  • Relative Humidity: 85% +/- 5%.
  • BTU/Hr. (approx.): 31 BTU/Hr.