Altronix T2PDK75F16S 16-Door Altronix/PDK Red™ Access and Power Integration Kit - Trove2PD2 with eFlow104NB, eFlow102NB, (2) ACMS8, VR6, PD8UL. Trove2 Series
Product Info
PDK 20A 16DR SYS/FUSE
Altronix T2PDK75F16S kit consists of Trove2 enclosure, TPD2 PDK Red™/Altronix backplane with one (1) 24VDC 10A, one (1) 12VDC 10A power supply/charger, two (2) eight (8) fuse protected dual input/output access control modules, one (1) 12VDC voltage regulator and one (1) eight (8) fuse protected power distribution modules. This kit also accommodates up to four (4) PDK Red™ modules for up to sixteen (16) doors in a single enclosure. Trove simplifies board layout and wire management, reduces installation time and labor costs.
eFlow104NB Power Supply/Charger – 1
Input
- Voltage: 120VAC, 60Hz, 4.5A.
- Main Fuse: 6.5A / 250V.
Output - Voltage: 24VDC @ 10A.
- Auxiliary: 1A (unswitched).
- Other: Overvoltage protection. Filtered and regulated.
eFlow102NB Power Supply/Charger – 2
Input
- Voltage: 120VAC, 60Hz, 3.5A.
- Main Fuse: 5A / 250V.
Output - Voltage: 12VDC @ 10A.
- Auxiliary: 1A (unswitched).
- Other: Overvoltage protection. Filtered and regulated.
Both Power Supplies
Battery Charging
- Capacity: 12VDC/12AH (2 within enclosure); 40AH/65AH (requires separate enclosure)
- Type: Sealed lead acid or gel type
- Failover: Upon AC loss, instantaneous.
(Batteries are sold separately).
Fire Alarm Disconnect
- Supervised: Latching or non-latching.
- EOL: 10K Resistor.
Supervision - AC Failure: Form “C” contacts.
- Battery: Form “C” contacts.
- Low DC Power Shutdown: Shuts down DC output terminals if battery voltage drops below 71-73% for 12V units and 70-75% for 24V units (depending on the power supply). Prevents deep battery discharge.
Indicators LED - AC Input: 120VAC is present.
- DC Output: Powered.
- Battery: Discharged or not connected.
VR6 Voltage Regulator
Input
- Voltage: 24VDC from eFlow104NB.
Output - Voltage: 12VDC.
- Current: 6A continuous.
- Other: Surge suppression.
Indicators LED - Input: 24VDC is present.
- Output: Powered.
PD8UL Power Distribution Module
Input
- Voltage: 12VDC from eFlow104NB.
Outputs - Voltage: 12VDC.
- Fuses: 3.5A/250V.
Indicators LED - Green LED: DC Output.
Two (2) ACMS8 Dual Input Access Power Controllers
Input - Voltage: 24VDC from eFlow104NB and 12VDC from VR6.
- Input Fuse: 15A / 32V.
Outputs - Voltage: 12VDC and/or 24VDC.
- Eight (8) independently controlled fused outputs:
a) Fail-Safe and/or Fail-Secure power outputs Form “C” Relays rated 28VAC or VDC @ 2.5A.
b) Auxiliary power outputs (unswitched).
c) Any combination of the above.
Outputs Ratings - Fuses: 3A/32V.
Indicators (LED’s) - Red LEDs: Outputs are triggered (relays energized).
- Green L
