FIRE-LITE ES-200XP, 198-PT FACP W/ CELLULAR/IP

Item #: FLT-ES-200XP

Product Info

FLT-ES200XP, FLTES200XP
FIRE-LITE
ES-200XP

198-POINT ADDRESSABLE FIRE ALARM CONTROL PANEL WITH BUILT-IN DUAL-PATH (IP/CELLULAR) DUAL-SIM (AT&T/VERIZON) 5G LTE-M COMMUNICATOR

The ES-200XP are the latest intelligent addressable Fire Alarm Control Panel (FACP) from Fire•Lite Alarms and is a direct replacement for the MS-9200UDLS. The ES-200XP features an integrated CLSS Pathway Pro Communicator, a dual-SIM (AT&T/ Verizon) 5G LTE-M Communicator with optional IP connection. The CLSS Pathway Pro transmits system status (alarms, troubles, AC loss, etc.) to the Central Station using LTE CAT-M1 networks, serving as a bridge between the fire system and the CLSS Cloud. The IP communicator’s Internet monitoring capability sends alarm signals over the Internet, meeting requirements for backup communication. As an integrated communicator, the CLSS Pathway Pro, typically, can transmit data faster than dial capture methods.

FEATURES:

  • Listed to UL Standard 864, 10th edition
  • Integrated CLSS Pathway Pro Communicator; dual SIM AT&T/Veri- zon networks with LTE-CAT-M1 5G technology
  • Cloud monitoring using Honeywell’s Connected Life Safety Services (CLSS) Cloud solutions software
  • Automated activation of the ECC-50/100 Emergency Command Center
  • ECC-FFT Firefighter Telephone option
  • Compatible with SWIFT® wireless devices
  • Auto-programming (learn mode) reduces installation time. Reports two devices set to the same address
  • Four built-in, independently programmable, Class A or Class B NAC circuits
  • Selectable strobe synchronization for System Sensor, Wheelock, and Gentex devices
  • Notification Appliance Circuit End of Line resistor matching • Four programmable function keys for ease of maintenance
  • Two programmable relays and one fixed trouble relay
  • Built-in Programmer
  • Integral 80-character LCD display with backlighting
  • Real-time clock/calendar with automatic daylight savings control
  • History file with 1,000 event capacity
  • Addressable sounder base compatibility
  • Multi-criteria detector (smoke, heat, CO) with programmable response
  • Control module delay timer
  • Automatic detector sensitivity testing (NFPA 72 compliant)
  • Automatic device type-code verification
  • Point trouble identification
  • Waterflow selection per module point
  • Alarm verification selection per detector point
  • Maintenance alert warns when smoke detector dust accumulation is excessive
  • One-person audible or silent walktest with walktest log and printout
  • System alarm verification selection per detector point
  • PAS (Positive Alarm Sequence) and Pre-signal per point (NFP A 72 compliant)
  • Up to 16 ANN-BUS annunciators- 8 per each ANN-Bus
  • Remote Acknowledge, Alarm Silence, Reset and Drill via addressable modules or remote annunciator