FIRE-LITE ES-50X Addressable Fire Alarm Control Panel with Communicator

Item #: FLT-ES-50X

Product Info

FLTES50X
FIRE-LITE
ES-50X

The ES-50X are the latest intelligent addressable fire alarm control panel (FACPs) from Fire•Lite Alarms and are direct replacement for the MS-9050UD. The ES-50X Series support up to 50 addressable devices in any combination of detectors or modules. With an extensive list of powerful features, the ES-50X Series programs just like Fire•Lite’s other addressable panels, yet fits into applications previously served only by conventional panels.

The ES-50X features a pre-installed IPOTS-COM, a dual technology (POTS and IP) communicator. The POTS transmits system status (alarms, troubles, AC loss, etc.) to a Central Station via the public switched telephone network. The IP communicator’s internet monitoring capability sends alarm signals over the Internet saving the monthly cost of two dedicated business telephone lines.

FEATURES:

  • Listed to UL Standard 864, 10th edition
  • Pre-installed IPOTS-COM Ethernet IP and POTS (Plain Old Telephone Service) Central Station Communicator (ES-50X and EX-50XC only)
  • Optional Cellular Central Station Communicators over AlarmNet®
  • Compatible with SWIFT® wireless devices
  • Auto-programming (learn mode) reduces installation time. Reports two devices set to the same address
  • Two independently programmable, built-in, Class A or Class B NAC circuits
  • Selectable strobe synchronization for System Sensor, Wheelock, and Gentex devices
  • Notification Appliance Circuit End of Line resistor matching
  • Four programmable function keys for ease of maintenance
  • Two programmable relays and one fixed trouble relay
  • Built-in Programmer
  • Integral 80-character LCD display with backlighting
  • Real-time clock/calendar with automatic daylight savings control
  • History file with 1,000 event capacity
  • Addressable sounder base
  • Multi-criteria detector (smoke, heat, CO) with programmable response
  • Control module delay timer
  • Automatic detector sensitivity testing (NFPA 72 compliant)
  • Automatic device type-code verification
  • Point trouble identification
  • Waterflow selection per module point
  • Alarm verification selection per detector point
  • Maintenance alert warns when smoke detector dust accumulation is excessive
  • One-person audible or silent walktest with walktest log & printout
  • System alarm verification selection per detector point
  • PAS (Positive Alarm Sequence) and Pre-signal per point (NFP A 72 compliant)
  • Up to 16 ANN-BUS annunciators- 8 per each ANN-Bus
  • Remote Acknowledge, Alarm Silence, Reset and Drill via addressable modules or remote annunciator